Minnetonka – 04/15/2015

Location: Minnetonka, MN

Cost: $1875

Initial Radon Level: 10.1 pCi/L

Post Mitigation Radon Level: 1.3 pCi/L

This was a classic Minnetonka home, similar to homes we install radon mitigation systems everyday.  There was a drain tile system that allowed us to collect radon from the entire basement.  We installed a sealed sump basket lid, with a viewport for easy viewing and access to the basket.

featured23-sump-basket

The suction point was installed in the other end of the basement and connected to the drain tile system.  The pipe runs up the basement wall and out into the garage.  In the garage each end of the radon pipe has a fire collar.  A u-tube was installed to easily know if the radon fan is still running.

featured23-basement
featured23-garage

The radon fan was installed in the attic and the electrical connection was supplied by a licensed electrician.  A white radon vent was used to match the other plumbing vents on the roof.

featured23-radon-fan
featured23-radon-vent